Lantern Roof Installation

Guide · Homeowners · 4 min read · Updated 17 November 2026

Roof Lantern Leaking? Causes, Condensation and How to Fix It

Short answer

Most roof lantern leaks come from the kerb and membrane junction, failed glazing seals, damaged ridge or hip caps, or blocked drainage channels. Water appearing in cold weather without rain is often condensation, caused by humid rooms and uninsulated kerbs. Small seal faults can be repaired, but old lanterns with misted units or failing frames are often best replaced on an upgraded kerb, from around £2,000.

Roof Lantern Leaking? Causes, Condensation and How to Fix It

Leak or condensation?

The first step is working out whether you have a leak or condensation, because the fixes are completely different. A leak lets rainwater in from outside, so water appears during or shortly after rain, often in the same spot each time. Condensation forms when warm, humid air inside the room meets a cold surface, usually in cold weather, and water appears on the inside of the glass, on the frame or at the base of the kerb.

Keep a note of when the water appears, the weather and what was happening in the room, such as cooking or drying washing. This simple record helps any installer diagnose the problem quickly.

SignLikely cause
Drips during or after rainLeak at kerb, seals or caps
Water on inside of glass in cold weatherCondensation
Misting between the two panesFailed sealed glazing unit
Damp patch on ceiling beside the lanternMembrane or kerb junction leak
Water at the base of the kerb onlyKerb condensation or leak
Mould on kerb liningsCold, uninsulated kerb

Common causes of leaks

The junction between the roof membrane and the kerb is the most common source of leaks. If the membrane was not taken far enough up the kerb, the kerb is too low, or the seal has failed through age or movement, water can track under the lantern frame. Damaged or poorly fitted ridge and hip caps can also let water in at the top of the lantern.

Glazing seals and gaskets deteriorate over time, especially on older lanterns and polycarbonate tops. Drainage channels and weep holes in the frame can become blocked with leaves and dirt, causing water to back up and overflow inside. Cracked panes and failed sealant around fixings are other possibilities.

  • Membrane not taken high enough up the kerb
  • Kerb too low, allowing water to pool against the frame
  • Worn glazing gaskets and seals
  • Damaged ridge or hip caps
  • Blocked weep holes and drainage channels
  • Cracked or damaged glazing

Why condensation happens

Condensation is common in kitchens and bathrooms where cooking, washing and bathing produce a lot of moisture. If the lantern frame or kerb is colder than the air in the room, water vapour condenses on it. Uninsulated kerbs are a frequent culprit, because the cold timber at the edge of the opening creates a cold strip around the lantern.

Older lanterns without thermally broken frames, and single-glazed or polycarbonate tops, are much more prone to condensation than modern double-glazed, thermally broken units. Poor ventilation in the room makes everything worse.

Reducing condensation

Improve ventilation first. Use cooker hoods and extractor fans, ideally ducted outside, and open trickle vents or windows where possible. Avoid drying washing in the room below the lantern. Keep the room evenly heated, as cold spells with intermittent heating encourage condensation.

If condensation persists, the kerb may need insulating, or the lantern may need upgrading to a modern thermally broken unit with better glazing. An installer can check the kerb construction and recommend the right fix. In many cases a combination works best: better extraction in the kitchen, steadier heating in winter and an insulated kerb. Upgrading only the lantern while leaving a cold, uninsulated kerb in place often moves the condensation to the edges rather than curing it.

Repair or replace?

Some problems can be repaired. Clearing blocked drainage channels, replacing worn gaskets, resealing caps and replacing a single failed glazing unit are all realistic repairs on a lantern that is otherwise in good condition. Membrane faults at the kerb can often be repaired by re-detailing the upstand.

Replacement makes sense when a lantern has multiple misted units, a failing frame, an old polycarbonate top or a kerb that is too low or uninsulated. A replacement lantern on an existing kerb typically starts from around £2,000, with the old lantern removed, the kerb resealed or upgraded and the new lantern fitted, often the same day.

Upgrading the kerb

If the kerb is the source of the problem, replacing the lantern alone may not solve it. A new insulated kerb or prefabricated upstand, typically £400–£1,000, raises the lantern to a sensible height above the roof finish, provides a proper surface for the membrane to seal against and removes the cold bridge that causes condensation. It is often worth doing at the same time as replacing an old lantern.

Replacing a rooflight is notifiable building work in England and Wales, so make sure your installer is registered with a competent person scheme or that building control is notified.

Getting help

Some simple checks are safe to do yourself from inside or from a window. Look for misted panes, discoloured or shrinking seals visible from below, staining on the kerb linings and leaves visible against the glass. Do not climb onto the roof to inspect the lantern unless you have safe access and are confident the roof will take your weight. Never stand on the lantern itself.

Lantern repairs involve working at height on a roof, which needs suitable access under the Work at Height Regulations 2005. We arrange vetted, insured local lantern installers who diagnose leaks and condensation, carry out repairs and fit replacements on upgraded kerbs where needed.

Questions people also ask

Why is my roof lantern leaking?

The most common causes are a failed seal where the roof membrane meets the kerb, worn glazing gaskets, damaged ridge or hip caps and blocked drainage channels in the frame. A kerb that is too low can let water pool against the frame. An installer can inspect the lantern to find the exact source.

How do I stop condensation on my roof lantern?

Improve ventilation in the room with extractor fans and trickle vents, avoid drying washing beneath it and keep heating steady. If condensation persists, the kerb may need insulating or the lantern upgrading to a thermally broken, double-glazed unit. Uninsulated kerbs are a frequent cause.

Can a misted roof lantern pane be replaced?

Yes. Misting between panes means the sealed glazing unit has failed, and individual units can usually be replaced without changing the whole lantern. If several panes are misted or the frame is old and failing, replacing the whole lantern on an upgraded kerb is often better value.

Written and checked by the Lantern Roof Installation team. Read our editorial policy.

Get a free lantern roof installation quote

Tell us what you need and we'll come back with a clear price.

Request a quote